{"id":3476,"date":"2026-02-02T22:37:24","date_gmt":"2026-02-02T22:37:24","guid":{"rendered":"https:\/\/vortice-latam.com\/?p=3476"},"modified":"2026-02-03T17:48:30","modified_gmt":"2026-02-03T17:48:30","slug":"ventilacion-de-bodegas-y-espacios-de-gran-volumen","status":"publish","type":"post","link":"https:\/\/vortice-latam.com\/es\/ventilacion-de-bodegas-y-espacios-de-gran-volumen\/","title":{"rendered":"Ventilaci\u00f3n de bodegas y espacios de gran volumen"},"content":{"rendered":"<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Las bodegas, naves industriales y espacios de gran volumen se han convertido en un dise\u00f1o recurrente para los sistemas de ventilaci\u00f3n por el gran auge industrial y la necesidad de espacios m\u00e1s grandes para las diferentes \u00e1reas de producci\u00f3n. Se trata de recintos con grandes alturas, amplias superficies y, en muchos casos, que presentan cargas t\u00e9rmicas importantes, generaci\u00f3n de contaminantes, polvo, vapores o acumulaci\u00f3n de aire caliente en zonas superiores.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Una ventilaci\u00f3n adecuada en este tipo de espacios no solo es fundamental para garantizar condiciones seguras y confortables para las personas, sino tambi\u00e9n para proteger los productos almacenados, mejorar la eficiencia operativa y cumplir con normativas t\u00e9cnicas y de seguridad industrial.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">En este contexto, los ventiladores axiales industriales, y en particular el ventilador HJB de Casals, se posiciona como una soluci\u00f3n altamente eficiente, flexible y robusta para aplicaciones en bodegas y recintos de gran volumen.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Este tipo de espacios presenta condiciones particulares que influyen directamente en el dise\u00f1o del sistema de ventilaci\u00f3n. Entre las m\u00e1s comunas se encuentran las grandes \u00e1reas en planta, alturas considerables, presencia de equipos y maquinaria, tr\u00e1nsito frecuente de personas y veh\u00edculos industriales, as\u00ed como la generaci\u00f3n de calor, polvo o contaminantes.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Estas condiciones hacen que la ventilaci\u00f3n natural sea, en muchos casos, insuficiente, por lo que se requiere la implementaci\u00f3n de sistemas de ventilaci\u00f3n mec\u00e1nica capaces de manejar grandes caudales de aire de forma eficiente.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<h2><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">C\u00e1lculo del volumen del recinto<\/span><\/span><\/span><\/span><\/span><\/span><\/h2>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">El primer paso para el dise\u00f1o de un sistema de ventilaci\u00f3n es determinar el volumen del espacio a ventilar. Este par\u00e1metro se obtiene a partir del \u00e1rea en planta del recinto y su altura promedio.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">En bodegas con techos inclinados o configuraciones irregulares, se recomienda utilizar una altura promedio representativa o realizar el c\u00e1lculo del volumen por secciones para casos que requieran mayor precisi\u00f3n. El volumen de estos espacios se calcula mediante: V = L * W * H<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Siendo:<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<ul>\n<li><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">V = Volumen<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">L = Largo<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">W = Ancho<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">H = Altura del espacio<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<\/ul>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">El volumen total del recinto es un factor clave, ya que constituye la base para el caudal de ventilaci\u00f3n requerido.<\/span><\/span><\/span><\/span><\/p>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Una vez determinado el volumen, se procede al c\u00e1lculo del caudal de aire necesario para garantizar una adecuada renovaci\u00f3n del aire interior. El m\u00e9todo m\u00e1s utilizado en bodegas y espacios de gran volumen es el basado en renovaciones de aire por hora.<\/span><\/span><\/span><\/span><\/p>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Las renovaciones de aire por hora representan cu\u00e1ntas veces el volumen total del recinto es reemplazado por aire fresco en una hora. El n\u00famero de renovaciones depende del uso del espacio, del nivel de ocupaci\u00f3n, de la presencia de contaminantes y de las condiciones t\u00e9rmicas. Para definir con precisi\u00f3n el n\u00famero de renovaciones de aire por hora en bodegas y espacios de gran volumen, es recomendable consultar las normativas t\u00e9cnicas y est\u00e1ndares internacionales que perfilan criterios y valores orientativos seg\u00fan el uso del espacio. Entre las referencias m\u00e1s reconocidas se encuentran la DIN 1946, as\u00ed como otros est\u00e1ndares sectoriales como la ASHRAE 62.1 o las gu\u00edas de la OSHA \/ NIOSH para ambientes industriales.<\/span><\/span><\/span><\/span><\/p>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">En estas normativas es posible encontrar diferentes m\u00e9todos de c\u00e1lculo, recomendaciones de renovaciones por hora y requisitos m\u00ednimos de ventilaci\u00f3n para diferentes tipos de recintos, facilitando un dise\u00f1o seguro, eficiente. En este tipo de espacios de gran volumen, se va a encontrar en el rango de 10 a 20 ren\/h.<\/span><\/span><\/span><\/span><\/p>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Este criterio permite definir con facilidad y de forma clara el caudal total que debe manejar el sistema de ventilaci\u00f3n. Para el c\u00e1lculo del caudal de los espacios de gran volumen o bodegas, se utiliza la siguiente f\u00f3rmula: Q <\/span><\/span><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">= V * N \u00a0<\/span><\/span><\/span><\/span><\/span><\/p>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Siendo:<\/span><\/span><\/span><\/span><\/p>\n<ul>\n<li><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Q = Caudal de aire (m <\/span><\/span><\/span><\/span><sup><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">3<\/span><\/span><\/span><\/span><\/sup><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"> \/ho CFM)<\/span><\/span><\/span><\/span><\/li>\n<li><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">V = Volumen del recinto<\/span><\/span><\/span><\/span><\/li>\n<li><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">N = N\u00famero de renovaciones hora (h <\/span><\/span><\/span><\/span><sup><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">-1<\/span><\/span><\/span><\/span><\/sup><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"> )<\/span><\/span><\/span><\/span><\/li>\n<\/ul>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">En bodegas de gran tama\u00f1o, el caudal total requerido suele ser elevado, por lo que es recomendable distribuirlo mediante varios ventiladores en lugar de concentrarlo en un solo equipo.<\/span><\/span><\/span><\/span><\/p>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">La distribuci\u00f3n del caudal en M\u00faltiples ventiladores permite mejorar la circulaci\u00f3n del aire, optimizar la ubicaci\u00f3n de los equipos, aumentar la confiabilidad del sistema y facilitar las labores de mantenimiento.<\/span><\/span><\/span><\/span><\/p>\n<h2><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Ventilador HJB<\/span><\/span><\/span><\/span><\/h2>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">El Ventilador HJB ha sido dise\u00f1ado espec\u00edficamente para aplicaciones industriales que requieren grandes caudales de aire, alta confiabilidad y flexibilidad de instalaci\u00f3n.<\/span><\/span><\/span><\/span><\/p>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Este equipo se caracteriza por su amplia gama de tama\u00f1os, lo que permite adaptarse a diferentes requisitos de caudal y configuraciones de montaje. Su dise\u00f1o lo hace ideal para instalaciones en muros, fachadas, cubiertas o en sistemas de conductos cortos.<\/span><\/span><\/span><\/span><\/p>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">El HJB ofrece una excelente relaci\u00f3n entre caudal, consumo energ\u00e9tico y costo de inversi\u00f3n, convirti\u00e9ndolo en una soluci\u00f3n eficiente para la ventilaci\u00f3n de bodegas y espacios de gran volumen.<\/span><\/span><\/span><\/span><\/p>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Gracias a su dise\u00f1o y variedad de configuraciones, puede emplearse tanto en sistemas de extracci\u00f3n como de inyecci\u00f3n de aire.<\/span><\/span><\/span><\/span><\/p>\n<p style=\"text-align: center;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><a href=\"https:\/\/vortice-latam.com\/es\/product\/ventilador-helicoidal-hjb\/\"> <img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3478 aligncenter\" src=\"https:\/\/vortice-latam.com\/wp-content\/uploads\/2026\/02\/images-5.jpg\" alt=\"\" width=\"225\" height=\"225\" srcset=\"https:\/\/vortice-latam.com\/wp-content\/uploads\/2026\/02\/images-5.jpg 225w, https:\/\/vortice-latam.com\/wp-content\/uploads\/2026\/02\/images-5-150x150.jpg 150w, https:\/\/vortice-latam.com\/wp-content\/uploads\/2026\/02\/images-5-100x100.jpg 100w\" sizes=\"auto, (max-width: 225px) 100vw, 225px\" \/><\/a><strong><em><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Haz clic en la imagen para m\u00e1s informaci\u00f3n sobre HJB Casals<\/span><\/span><\/em><\/strong><\/span><\/span><\/p>\n<p><a href=\"https:\/\/vortice-latam.com\/es\/product\/ventilador-helicoidal-hjb\/\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3481 aligncenter\" src=\"https:\/\/vortice-latam.com\/wp-content\/uploads\/2026\/02\/image-3.jpg\" alt=\"\" width=\"1000\" height=\"235\" srcset=\"https:\/\/vortice-latam.com\/wp-content\/uploads\/2026\/02\/image-3.jpg 1000w, https:\/\/vortice-latam.com\/wp-content\/uploads\/2026\/02\/image-3-300x71.jpg 300w, https:\/\/vortice-latam.com\/wp-content\/uploads\/2026\/02\/image-3-768x180.jpg 768w, https:\/\/vortice-latam.com\/wp-content\/uploads\/2026\/02\/image-3-416x98.jpg 416w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/a><\/p>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Puede utilizarse para evacuar aire caliente o contaminado, introducir aire fresco desde el exterior o combinar ambas funciones para lograr un sistema equilibrado y eficiente. De esta manera, permite adaptar los dise\u00f1os a las necesidades espec\u00edficas de cada proyecto con completa versatilidad.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Al dise\u00f1ar sistemas de ventilaci\u00f3n para bodegas utilizando ventiladores HJB, es importante considerar la correcta ubicaci\u00f3n de los equipos, la disponibilidad de aberturas para la entrada de aire y la posibilidad de futuras ampliaciones del recinto. Un dise\u00f1o adecuado garantiza un funcionamiento eficiente, seguro y confiable a lo largo del tiempo.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">La ventilaci\u00f3n de bodegas y espacios de gran volumen requiere un an\u00e1lisis cuidadoso del volumen del recinto y del caudal de aire necesario para asegurar una adecuada renovaci\u00f3n.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p>El ventilador HJB, gracias a su robustez, amplia gama de tama\u00f1os como lo son el HJB 90, 110, 120 y 140. Estos equipos dan la posibilidad de alcanzar caudales desde los 9 mil CFM hasta los 24 mil CFM y con la versatilidad de instalaci\u00f3n que ofrecen estos equipos, se consolida como una soluci\u00f3n ideal para este tipo de aplicaciones, ofreciendo una gran eficiencia energ\u00e9tica, la confiabilidad que la marca de Casals brinda con sus m\u00e1s de 100 a\u00f1os de experiencia en el mercado y la adaptabilidad que brinda su dise\u00f1o a gran variedad de escenarios industriales.<\/p>\n<p><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\"><span dir=\"auto\" style=\"vertical-align: inherit;\">Ing Emmanuel Fern\u00e1ndez Vortice Vortice Latam<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Las bodegas, naves industriales y espacios de gran volumen se han convertido en un dise\u00f1o recurrente para los sistemas de ventilaci\u00f3n por el gran auge industrial y la necesidad de espacios m\u00e1s grandes para las diferentes \u00e1reas de producci\u00f3n. Se trata de recintos con grandes alturas, amplias superficies y, en muchos casos, que presentan cargas [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3477,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[42],"tags":[],"class_list":["post-3476","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/vortice-latam.com\/es\/wp-json\/wp\/v2\/posts\/3476","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vortice-latam.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/vortice-latam.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/vortice-latam.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/vortice-latam.com\/es\/wp-json\/wp\/v2\/comments?post=3476"}],"version-history":[{"count":9,"href":"https:\/\/vortice-latam.com\/es\/wp-json\/wp\/v2\/posts\/3476\/revisions"}],"predecessor-version":[{"id":3489,"href":"https:\/\/vortice-latam.com\/es\/wp-json\/wp\/v2\/posts\/3476\/revisions\/3489"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/vortice-latam.com\/es\/wp-json\/wp\/v2\/media\/3477"}],"wp:attachment":[{"href":"https:\/\/vortice-latam.com\/es\/wp-json\/wp\/v2\/media?parent=3476"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/vortice-latam.com\/es\/wp-json\/wp\/v2\/categories?post=3476"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/vortice-latam.com\/es\/wp-json\/wp\/v2\/tags?post=3476"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}